Product Details:
Payment & Shipping Terms:
|
Body: | Aluminum | Core And Plugnut: | Stainless Steel |
---|---|---|---|
Core Spring: | Stainless Steel | Working Pressure: | 0.35-0.85Mpa |
Sealing & Disc: | CR (chloroprene) | Diaphragm: | NBR(nitrile/buna-n) Or Viton |
Diaphragm Seat: | PA-6 (standard) | Port Size: | 3 " |
High Light: | Goyen Diaphragm Valves,Diaphragm Pulse Valve |
Goyen Aluminum dust collect diaphragm valve CA76T 010-305 3 " DC24V pulse jet valve
Operation :
Recommended on time range: 50-500ms
Recommended time between pulses: 1 minute or greater
Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
Constuction Material:
Body | Aluminium (diecast) |
Ferrule | 304 SS |
Armature | 430FR SS |
Seals | Nitrile or Viton (reinforced) |
Spring | 304 SS |
Screws | 302 SS |
Clip | Mild steel (plated) |
Locknut | Mild steel zinc passivated |
Voltage | DC: 24V, AC: 24V,48V,110V,230V |
Working Temperature | - 20 to + 85 ℃ |
Protection Class | IP65 |
Coil Insulation Class | F |
Working Pressure | 0.35-0.85Mpa |
Diaphragm Seat | PA-6 or Viton coated mild steel or High Density PE |
Sealing & disc | CR (chloroprene) |
Diaphragm | NBR(nitrile/buna-n) or Viton |
Shading coil | Copper |
Connector | DIN43650A |
Weight:
Size | Integral Pilot | Remote Pilot |
(CA) Kg (lbs) | (RCA) Kg (lbs) | |
20 | 0.60 ( 1.31 ) | 0.38 ( 0.83 ) |
25 | 0.73 ( 1.61 ) | 0.51 ( 1.13 ) |
35 | 1.04 ( 2.28 ) | 0.83 ( 1.83 ) |
45 | 1.50 ( 3.30 ) | 1.28 ( 2.83 ) |
50 | 2.89 ( 6.38 ) | 2.68 ( 5.92 ) |
62 | 3.31 ( 7.30 ) | 3.09 ( 6.82 ) |
76 | 4.77 ( 10.52 ) | 4.56 ( 10.04 ) |
Option:
1 | Waterproof enclosure with embedded screw terminal coil according to protection class IP67, CEE 10 |
2 | Explosionproof solenoids for hazardous locations according to “ATEX” (CENELEC) and national standards |
3 | Explosionproof and watertight solenoids according to “NEMA” standards |
4 | Hose connection executions (3" only) |
5 | Compliance with “UL” standards |
6 | Plug with visual indication and/or peak voltage suppression |
7 | Electronic timer |
8 | Valves can also be supplied with FPM (fluorelastomer) diaphragms and seals. Use the appropriate suffix letter for identification |
Maintenance:
Before conducting any maintenance activity on the system ensure that components are fully isolated from
pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled.
Diaphragm and pilot inspection should be conducted annually
DIMENSIONS (mm) :
Product show:
Fitted Repair kits code: Diaphragm K7600 / K7601(Vition)