Product Details:
Payment & Shipping Terms:
|
Body: | Aluminum | Core And Plugnut: | Stainless Steel |
---|---|---|---|
Core Spring: | Stainless Steel | Working Pressure: | 0.35-0.85Mpa |
Sealing & Disc: | CR (chloroprene) | Diaphragm: | NBR(nitrile/buna-n) Or Viton |
Diaphragm Seat: | PA-6 (standard) | Port Size: | 1" |
High Light: | Goyen Diaphragm Valves,Dust Collector Pulse Valves |
Goyen Aluminum diaphragm valve CA25T 010-305 1 " DC24V pulse jet valve
Description
High performance diaphragm valve with threaded ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.
Constuction Material:
Body | Aluminium (diecast) |
Ferrule | 304 SS |
Armature | 430FR SS |
Seals | Nitrile or Viton (reinforced) |
Spring | 304 SS |
Screws | 302 SS |
Clip | Mild steel (plated) |
Locknut | Mild steel zinc passivated |
Voltage | DC: 24V, AC: 24V,48V,110V,230V |
Working Temperature | - 20 to + 85 ℃ |
Protection Class | IP65 |
Coil Insulation Class | F |
Working Pressure | 0.35-0.85Mpa |
Diaphragm Seat | PA-6 or Viton coated mild steel or High Density PE |
Sealing & disc | CR (chloroprene) |
Diaphragm | NBR(nitrile/buna-n) or Viton |
Shading coil | Copper |
Connector | DIN43650A |
Weight:
Size | Integral Pilot | Remote Pilot |
(CA) Kg (lbs) | (RCA) Kg (lbs) | |
20 | 0.60 ( 1.31 ) | 0.38 ( 0.83 ) |
25 | 0.73 ( 1.61 ) | 0.51 ( 1.13 ) |
35 | 1.04 ( 2.28 ) | 0.83 ( 1.83 ) |
45 | 1.50 ( 3.30 ) | 1.28 ( 2.83 ) |
50 | 2.89 ( 6.38 ) | 2.68 ( 5.92 ) |
62 | 3.31 ( 7.30 ) | 3.09 ( 6.82 ) |
76 | 4.77 ( 10.52 ) | 4.56 ( 10.04 ) |
INSTAllATION:
1 | The valves can be mounted in any position without affecting operation |
2 | Threaded pipe connection is: G = G (ISO 228/1) or compression fittings |
3 | When connecting piping or tubing to the G1/8 connection in the valve bonnet, the remote pilot valve should be mounted as close as possible to the main pulse valve. Connection tubing lengths of 3 meter or less have little effect on the pulse response. Installations with over 3 meter of tubing must be tested under actual operating conditions. Tubing with Ø 6 mm O.D. is recommended for all installations |
4 | Spare parts kit and replacement coils are available |
5 | Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank. |
6 | Ensure tank and pipes are free from dirt, rust or other particulate. |
7 | Ensure supply air is clean and dry. |
Maintenance:
Before conducting any maintenance activity on the system ensure that components are fully isolated from
pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled.
Diaphragm and pilot inspection should be conducted annually
Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
DIMENSIONS (mm) :
Product show:
Fitted Repair kits code: Diaphragm K2501 / K2503(Vition)