Product Details:
Payment & Shipping Terms:
|
Body: | Aluminum | Core And Plugnut: | Stainless Steel |
---|---|---|---|
Core Spring: | Stainless Steel | Working Pressure: | 0.35-0.85Mpa |
Sealing & Disc: | CR (chloroprene) | Diaphragm: | NBR(nitrile/buna-n) Or Viton |
Diaphragm Seat: | PA-6 (standard) | Port Size: | 2" |
High Light: | Goyen Diaphragm Valves,Diaphragm Pulse Valve |
Goyen Cast Remote Pilot Aluminum diaphragm valve RCA50T 2 " pulse jet valve
Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
The high quality diaphragms are reinforced and wear resistant to guarantee a long operating life, even under harsh conditions
Constuction Material:
Body | Aluminium (diecast) |
Seals | Nitrile or Viton (reinforced) |
Spring | 304 SS |
Screws | 302 SS |
Clip | Mild steel (plated) |
Locknut | Mild steel zinc passivated |
Working Temperature | - 20 to + 85 ℃ |
Working Pressure | 0.35-0.85Mpa |
Diaphragm Seat | PA-6 or Viton coated mild steel or High Density PE |
Sealing & disc | CR (chloroprene) |
Diaphragm | NBR(nitrile/buna-n) or Viton |
Shading coil | Copper |
Description
High performance diaphragm valve with threaded ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.
Weight:
Size | Integral Pilot | Remote Pilot |
(CA) Kg (lbs) | (RCA) Kg (lbs) | |
20 | 0.60 ( 1.31 ) | 0.38 ( 0.83 ) |
25 | 0.73 ( 1.61 ) | 0.51 ( 1.13 ) |
35 | 1.04 ( 2.28 ) | 0.83 ( 1.83 ) |
45 | 1.50 ( 3.30 ) | 1.28 ( 2.83 ) |
50 | 2.89 ( 6.38 ) | 2.68 ( 5.92 ) |
62 | 3.31 ( 7.30 ) | 3.09 ( 6.82 ) |
76 | 4.77 ( 10.52 ) | 4.56 ( 10.04 ) |
INSTAllATION:
1 | When connecting piping or tubing to the G1/8 connection in the valve bonnet, the remote pilot valve should be mounted as close as possible to the main pulse valve. Connection tubing lengths of 3 meter or less have little effect on the pulse response. Installations with over 3 meter of tubing must be tested under actual operating conditions. Tubing with Ø 6 mm O.D. is recommended for all installations |
2 | Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank. |
3 | Ensure tank and pipes are free from dirt, rust or other particulate. |
4 | Apply moderate pressure to system and check for installation leaks. |
5 | For compression fitting types tightness is achieved by the compressed gasket on the blow tube |
6 | Other pipe threads are available on request |
7 | Installation/maintenance instructions are included with each valve |
8 | Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only). |
9 | Fully pressurise system. |
10 | Test fire and listen for proper actuation and crisp pulse noise. |
Maintenance:
Before conducting any maintenance activity on the system ensure that components are fully isolated from
pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled.
Diaphragm and pilot inspection should be conducted annually
DIMENSIONS (mm) :
Product show:
Fitted Repair kits code: Diaphragm K5000 / K5004(Vition)